Outcomes of Fluoroscopy‑Free Interlocking Intramedullary Nailing Using a Dedicated Targeting Device: A Prospective Analytical Study of 150 Femoral and Tibial Shaft Fractures in Abidjan
Résultats de l’Enclouage Centromédullaire Verrouillé sans Fluoroscopie Utilisant un Système de Visée Dédié : Une Étude Prospective Analytique de 150 Fractures Diaphysaires Fémorales et Tibiales à Abidjan.
DOI:
https://doi.org/10.5281/zenodo.20096794Keywords:
Diaphyseal fractures, Fluoroscopy, Interlocking intramedullary nailing, Nail locking, TreichvilleAbstract
ABSTRACT
Introduction. Interlocking intramedullary nailing is the gold standard for diaphyseal fractures, but it usually requires fluoroscopic guidance. In many low‑resource settings, fluoroscopy is not readily available. This study sought to evaluate the outcomes of interlocking nailing performed without fluoroscopy using a dedicated instrumentation system with a distal targeting device. Methods. This prospective analytical study was conducted from January 2021 to December 2024. We assessed the accuracy of the nail entry point, nail insertion depth, and the success rates of proximal and distal locking. Distal locking was considered successful when the screw passed through the corresponding nail hole on postoperative radiographs. Results. We included 136 patients (150 osteosyntheses: 68 femoral, 82 tibial). The entry point was optimal in 89.7% of femoral and 86.5% of tibial nails. Adequate nail depth was achieved in 79.4% of femoral and 92.6% of tibial procedures. Proximal locking succeeded in all patients. Distal locking succeeded in 75% of femoral and 86.5% of tibial cases. Successful distal locking was strongly associated with correct entry point placement (p=0.00027) and proper nail impaction (p=0.00000007). Conclusion. Proximal locking was consistently achieved without fluoroscopic guidance. Distal locking had a higher success rate in tibial than in femoral fractures. Fluoroscopy‑free interlocking nailing is feasible and, when correctly performed, eliminates radiation exposure.
RÉSUMÉ
Introduction. L’enclouage centromédullaire verrouillé est la référence dans le traitement des fractures diaphysaires des os longs. Il est habituellement réalisé sous amplificateur de brillance. Le but de cette étude était d’analyser le résultat du verrouillage sans amplificateur de brillance, à l’aide d’un ancillaire avec un dispositif de visée distale. Patients et Méthodes. L’étude était prospective analytique de Janvier 2021 à Décembre 2024. Les paramètres évalués étaient le point d’entrée du clou, son enfoncement et le succès du verrouillage. Au fémur le point d'entrée idéal se situait sur le sommet du grand trochanter à la jonction de son tiers antérieur et de ses deux-tiers postérieurs. Au tibia il se trouvait au milieu du plateau et au-dessus du niveau de la tubérosité tibiale. Les verrouillages proximal et distal étaient réalisés à l’aide d’un viseur rattaché à la partie latérale de l’ancillaire, avec un angle de visée perpendiculaire à l’axe du clou. Compte-tenu des contraintes importantes sur le clou, le verrouillage distal était parfois faussé et jugé sur les radiographies de contrôle postopératoires comme un échec lorsque la vis ne passait pas dans le trou correspondant sur le clou. Résultats. Le point d’entrée était bon dans 89,7% des clous fémoraux et 86,5% des clous tibiaux. L’enfoncement était bon dans 79,4% des cas au fémur et 92,6% au tibia. Le verrouillage proximal était réussi chez tous les patients, et le distal à 75% au fémur et 86,6% au tibia. Le succès du verrouillage distal dépendait de la précision du point d’entrée du clou (p=0,00027) et de son bon enfoncement (p=0,00000007). Conclusion. Le verrouillage était toujours réalisé avec succès en proximal. En distal, il était plus réussi au niveau du tibia qu’au fémur. Il est possible sans amplificateur de brillance et sa bonne réalisation permet d’éviter l’exposition aux rayons x.
References
Mobiot AC, Traoré A, Kacou AD, Soumaro KD, Boka ER, Yapo AR et al. Verrouillage distal sans amplificateur de brillance sur table ordinaire des fractures diaphysaires du fémur: Analyse des résultats préliminaires. Rev Int Sc Méd. 2016; 18(4): 286-91.
2. Bonnomet F, Clavert P, Cognet JM. Fractures de la diaphyse fémorale de l’adulte. EMC-Appareil locomoteur 2006 : 1-23 [14-078-A-10].
3. Küntscher BG. The Küntscher method of intramedullary fixation. J Bone Jt Surg Am. 1958; 40: 17-26.
4. Kempf I, Grosse A, Lafforgue D. L’apport du verrouillage dans l’enclouage centromédullaire des os longs. Rev Chir Orthop. 1978; 64: 631-51.
5. Amossou LF, Goukodadja O, Padonou A, Chigblo P, Djagbé M, Hans-Moévi AA. Locked Centromedullary Nailing of the Tibia and Femur Without a Brilliance Amplifier in Benin: A Report of 180 Cases. Health Sci Dis. 2024; 25(4): 59-63.
6. Ogunlusi JD, St Rose RSGB, Davids T. Interlocking nailing without imaging: the challenges of locating distal slots and how to overcome them in SIGN intramedullary nailing. Int Orthop. 2010; 34(6): 891-5.
7. Teissier V, Diviné P, Mebtouche N, Auregan JC, Bégué T. Enclouage centromédullaire à verrouillage automatique Centronaily-étude préliminaire de faisabilité et d’utilité. Rev Chir Orthop Traumatol. 2015; 101(7): S163.
8. Dugas R, D’Ambrosia R. The Grosse-Kempf interlocking nail: technique of femoral and tibial fractures. Orthopedics. 2013; 8(11): 1363-70.
9. Arlettaz Y. Verrouillage distal des clous centromédullaires, évolution, état de l’art. Maitrise Orthopédique. 2013; (220): 9-12.
10. Stathopoulos I, Karampinas P, Evangelopoulos DS, Lampropoulou-Adamidou K, Vlamis J. Radiation-free distal locking of intramedullary nails: evaluation of a new electromagnetic computer-assisted guidance system. Injury. 2013; 44(6): 872-5.
11. Moor BK, Ehlinger M, Arlettaz Y. Distal locking of femoral nails. Mathematical analysis of the appropriate targeting range. Orthop Traumatol Surg Res. 2012; 98(1): 85-9.
12. Ehlinger M, Taglang G, Adam P, Bonnomet F. Viseur externe pour le verrouillage distal du clou gamma® long: DTD (distal targeting device). Etude prospective comparative à la technique classique à main levée. Maîtrise orthopédique. 2013; 220: 8-9.
13. Gugala Z, Nana A, Lindsey RW. Tibial intramedullary nail distal interlocking screw placement: comparison of the free-hand versus distally-based targeting device techniques. Injury. 2001; 32: 21-5.
14. Nzanzu ES, Mokassa LB, Kinshasa RD. Issue de l’enclouage centromédullaire verrouillé du fémur et du tibia dans deux hôpitaux en République démocratique du Congo. Rev Med Gd Lacs. 2021; 12(3): 37-43.
15. Guifo ML, Muluem OK, Farikou I, Ngongang FO, Tekpa B, Ndoumbe A. Enclouage centromédullaire verrouillé sans amplificateur de brillance au CHU de Yaoundé : à propos de 34 cas. Rev Chir Orthop Traumatol. 2016; 102(1): 101‑6.
16. Krettek C, Stephan C, Schandelmaier P, Richter M, Pape HC, Miclau T. The use of Poller screws as blocking screws in stabilising tibial fractures treated with small diameter intramedullary nails. J Bone Jt Surg Br. 1999; 81: 963 8.
17. Ikepeme I, Ngim N, Udosen A, Obiora O, Okokon E, Segun B. External jig-aided intramedullary interlocking nailing of diaphyseal fractures: experience from a tropical developing centre. Int Orthop 2011; 35: 107–11.
18. Sekimpi P, Okike K, Zirkle L, Jawa A. Femoral fracture fixation in developping countries: an evaluation of the Surgical Implant Generation Network (SIGN) Intramedullary nail. J Bone Joint Surg Am 2011; 93: 1811-8.
19. Bong MR, Kummer FJ, Koval KJ, Egol KA. Intramedullary nailing of the lower extremity: biomechanics and biology. J Am Acad Orthop Surg. 2007; 15: 97-106.
20. Krettek C, Mannss J, Konemann B, Miclau T, Schandelmaier P, Tscherne H. The deformation of small diameter solid tibial nails with unreamed intramedullary insertion. J Biomech. 1997; 30(4): 391-4.
21. Krettek C, Miclau T, Schandelmaier P, Stephan C, Möhlmann U, Tscherne H. The mechanical effect of blocking screws (“Poller screws”) in stabilizing tibia fractures with short proximal or distal fragments after insertion of small diameter intramedullary nails. J Orthop Trauma. 1999; 13: 550-3.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Bizolé Balepna DY, Sainy KSD, Yépié A, Traoré M, Kouame KM, Anoumou NM

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License CC BY-NC-ND 4.0 that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work